INSREF
Digital Non CFC Low Temperature
Calibration Bath, Cat. No. IRI 014
Polished
Stainless Steel tank of filling volume 10 -12 ltrs and overall size
300 mm x 200 mm z 200 mm (D)
Capacity of upto 8 probes of dia 19 mm & length 200mm
Stirrer for uniform temperature in tank
Long - life stainless steel immersion heater to maintain temperature
extra long cold zone
All other wetted parts are also of stainless steel
Tank insulation is formed-in-place Polyurethane Foam (PUF)
Operating temperature rang as per table below
Digital proportional, fully solid state temperature control
Accuracy of temperature control better than ±0.1oC
at minimum temperature
Digital temperature display with resolution (least
count) of 0.1oC
Accuracy of temperature display ±
0.5% of full range ± 1 digit
High temperature safety cut-off for heater (over temperature
protection)
Cooling is by air cooled, fully balanced, long life mechanical
systems, with single or
double stages (as required ) using hermetically sealed compressors
and
environment friendly, non- CFC gases
For double stage systems, necessary safety cut-offs
are built - in to allow unattended operation
Built-in Voltage Stabilizer with high & low voltage cut-off is
provided to protect
compressors from erratic power supply
Powder coated, compact, double color exterior with pipe framework
& sheet covers,
with large powder coated aluminum top
Lid with requisite ports to accommodate 8 probes of dia up to 19 mm
freely and 1 port for reference thermometer
Optional adapters to hold probes of smaller dia
Easy to operate & maintain, with detachable controller for
ease-of-recalibration
Available in two formats - floor standing (shown alongside) with
wheels for easy mobility and table top
Cat.
No. |
Lowest
Operating
Temperature |
Maximum
Operating
Temperature |
Maximum
Outer Dimensions
(Cross Section / Height) |
Cooling
Capacity
(Watts) |
Max.
Power
Required |
Table
Top |
Floor
(excluding wheels
of height 60 mm) |
AT
0oC |
AT
-40oC |
IRI
014 A |
-10oC |
40oC |
650mm
x
700mm
x
480mm (H) |
600mm
x
475mm
x
750mm (H) |
260 |
NA |
2.5
KVA |
IRI
014 C |
-20oC |
480 |
NA |
3
KVA |
IRI
014 E |
-30oC |
675 |
NA |
4
KVA |
IRI
014 G |
-40oC |
0oC
|
NOT
AVAILABLE AS A STANDARD OPTION
|
750 |
250 |
4
KVA |
IRI
014 H |
-50oC |
800mm
x 650mm
x900mm (H) |
850 |
320 |
5
KVA |
IRI
014 I |
-70oC |
850 |
320 |
35
KVA |
Lowest
temperatures typically reach within 90 to 120 minutes, at an ambient
of 27oC to 30oC. The lowest reachable
temperature varies with ambient temperature, quality & nature of
tank media and level of equipment maintenance. An air-conditioned
environment is most suited, though not absolutely necessary.
While calculating space requirements based on the above data, please
take into account free air circulation space of at least 300 mm on
all sides of the equipment.
Suggested tank liquids are distilled water for operating
temperatures above 5oC and good quality methanol for
operating temperatures below 5oC.
The Digital Temperature Display is calibrated at our factory against
thermometers which have calibration certificates traceable to
national standards. Calibration Certificates from a Government of
India lab, traceable to national standards for individual equipment
can be given, at extra cost.
It is suggested that models with Cat. No. IRI 014 H & IRI 014 I
are used consistently only at temperatures lower than -20oC,
and only intermittently for higher temperatures.
OPTIONS
AVAILABLE
Smaller / larger tank sizes - Smaller frame sizes - Higher Maximum
Temperatures
Higher Cooling Capacities - Calibration Certificates - Lid with
different port sizes - Adapters for various probe sizes
WHILE
ORDERING, PLEASE INDICATE CHOICE OF TABLE TOP OR FLOOR FORMAT
IF THERE IS NO SUCH INDICATION, ONLY FLOOR FORMAT WILL BE SUPPLIED
Actual
equipment may very from pictorial representation above.
Specifications are subject to change without notice.
|