INSREF Digital Non CFC Low Temperature
Calibration Bath, Cat. No. IRI 014


Polished Stainless Steel tank of filling volume 10 -12 ltrs and overall size 300 mm x 200 mm z 200 mm (D)
Capacity of upto 8 probes of dia 19 mm & length 200mm
Stirrer for uniform temperature in tank 
Long - life stainless steel immersion heater to maintain temperature extra long cold zone 
All other wetted parts are also of stainless steel
Tank insulation is formed-in-place Polyurethane Foam (PUF)

Operating temperature rang as per table below 
Digital proportional, fully solid state temperature control 
Accuracy of temperature control better than ±0.1oC at minimum temperature 
Digital temperature  display with  resolution (least count) of 0.1oC
Accuracy of temperature display  ± 0.5% of full range ± 1 digit
High temperature safety cut-off for heater (over temperature protection)

Cooling is by air cooled, fully balanced, long life mechanical systems, with single or
double stages (as required ) using hermetically sealed compressors and 
environment friendly, non- CFC gases
For double stage systems, necessary safety cut-offs
are built - in to allow unattended operation
Built-in Voltage Stabilizer with high & low voltage cut-off is provided to protect 
compressors from erratic power supply

Powder coated, compact, double color exterior with pipe framework & sheet covers, 
with large powder coated aluminum top
Lid with requisite ports to accommodate 8 probes of dia up to 19 mm freely and 1 port for reference thermometer
Optional adapters to hold probes of smaller dia
Easy to operate & maintain, with detachable controller for ease-of-recalibration
Available in two formats - floor standing (shown alongside) with wheels for easy mobility and table top

Cat. No. Lowest
Operating
Temperature 
Maximum
Operating
Temperature
Maximum Outer Dimensions
(Cross Section / Height)
Cooling Capacity
(Watts)
Max. 
Power
Required
Table Top Floor 
(excluding wheels
 of height 60 mm)
AT
0oC
AT
-40oC
IRI 014 A -10oC 40oC 650mm
x
700mm
x
480mm (H)
600mm
x
475mm
x
750mm (H)
260 NA 2.5 KVA
IRI 014 C -20oC 480 NA 3 KVA
IRI 014 E -30oC 675 NA 4 KVA
IRI 014 G -40oC

0oC

NOT AVAILABLE AS A STANDARD OPTION

750 250 4 KVA
IRI 014 H -50oC 800mm x 650mm
x900mm (H)
850 320 5 KVA
IRI 014 I -70oC 850 320 35 KVA

Lowest temperatures typically reach within 90 to 120 minutes, at an ambient of 27oC to 30oC. The lowest reachable  temperature varies with ambient temperature, quality & nature of tank media and level of equipment maintenance. An air-conditioned environment is most suited, though not absolutely necessary.

While calculating space requirements based on the above data, please take into account free air circulation space of at least 300 mm on all sides of the equipment.

Suggested tank liquids are distilled water for operating temperatures above 5oC and good quality methanol for operating temperatures below 5oC.

The Digital Temperature Display is calibrated at our factory against thermometers which have calibration certificates traceable to national standards. Calibration Certificates from a Government of India lab, traceable to national standards for individual equipment can be given, at extra cost.

It is suggested that models with Cat. No. IRI 014 H & IRI 014 I are used consistently only at temperatures lower than -20oC, and only intermittently for higher temperatures.

OPTIONS AVAILABLE
Smaller / larger tank sizes - Smaller frame sizes - Higher Maximum Temperatures
Higher Cooling Capacities - Calibration Certificates - Lid with different port sizes - Adapters for various probe sizes


WHILE ORDERING, PLEASE INDICATE CHOICE OF TABLE TOP OR FLOOR FORMAT
IF THERE IS NO SUCH INDICATION, ONLY FLOOR FORMAT WILL BE SUPPLIED


Actual equipment may very from pictorial representation above. Specifications are subject to change without notice.