Used
for determination of Kinematic & Intrinsic Viscosity of fuels,
lubricants & petrochem raw materials at constant temperatures,
in accordance with ASTM D 445 and equivalent methods, at
temperatures between –80 deg C to 100 deg C
User
categories include lubes & petroleum refineries; lubes &
petroleum storage & distribution installations; rerefiners;
chemicals, fertilizer & petrochemical
plants; synthetic fiber manufacturers; research & development
and quality control labs …..
Click
here for Users list
|
Cat.No.IRI
016 E HR
|
6A INSREF
Digital Viscometer Bath, Cat. No. IRI 016
…for 5oC above ambient to 120oC, optionally up to
199oC
Used for determination of Kinematic Viscosity at
temperatures from 5o C above ambient to 120o C.
Can be used for temperature around ambient and below with the help
of cooling coil1 in combination with a circulating
cryostat2 or lab chilled water supply.
Click
here for Specification Sheet.
Cat.
No. IRI 016 HR |
INSREF
Digital Viscometer Bath |
|
Generally
as per requirements under ASTM D 445 & equivalent
Operating Temperature range of 50C above ambient
to 1200C
Digital Display with resolution of 0.010C
Proportional temperature control to within ±
0.010C @ 400C & 1000C
Long life, high safety zone, stainless steel immersion heaters
Automatic boost heating
Automatic high temperature & low water level safety cut-off
Tray to hold viscometers attached to viscometer holersnes3,
having 3- point
alignment facility for each viscometer and port for reference
thermometer
With long life, low wattage, compact fluorescent lighting attachment
to enhance
sample & viscometer visibility
|
Cat. No. IRI 016 A HR |
With capacity of 4 Viscometers |
Cat. No. IRI 016 C HR |
With capacity of 8 Viscometers |
Cat. No. IRI 016 E HR |
With capacity of 2 Viscometers
|
Accessory
16-011 |
Coil
for circulation of chilled water |
Accessory
16-022 |
Digital,
Non CFC, Ultra Cryostat Circulator to extend operating temperature
from 50 C to 600 C (Cat. No. IRI 017 A) |
Accessory
16-033 |
Viscosity
holder, universal type |
Accessory
16-04 |
Back-up
system to take over in case of power failure, (to enable uninterrupted
control operation only) for up to 4 hrs continuous |
OPTIONAL |
Extended
temperature range up to 1900C (control accuracy ±
0.10C) |
Accessory
16-05 |
Pump-cum-stirrer,
output of 3-4 ltrs / min at zero head (control accuracy ±
0.10C) |
Custom
Designs |
With
larger / smaller tanks, better accuracy, higher upper and temperature
…… |
Calibration
Certificate |
For
the digital display, at minimum 3 points, traceable to national
standards from a Govt. of India Lab |
6B INSREF
Digital Below Ambient Viscometer Bath, Cat. No. IRI 019 HR
…for
100C to 400C, with non CFC refrigeration
Used
for determination of Kinematic Viscosity at temperatures from 100C
to 400 C. Provided with built-in non-CFC refrigeration
system.
Click
here for Specification Sheet.
Cat.
No. IRI 019 HR |
INSREF
Digital Below Ambient Viscometer Bath |
|
Generally
as per requirements under ASTM D 445 & equivalent
Operating Temperature range of 100 C to 400C
Digital Display with resolution of 0.010 C
Proportional temperature Control to within ± 0.010C
@ 250 C
Long
life, high safety zone, stainless steel immersion heaters
Automatic high temperature & low water level safety
cut-off
Tray to hold viscometers attached to viscometer holers1,
having 3- point alignment
facility for each viscometer and port for reference thermometer
With long life, low wattage, compact fluorescent lighting attachment
to enhance
sample & viscometer visibility
Built-in non CFC refrigeration system
|
Cat. No. IRI 019
A HR |
With capacity of 4 Viscometers |
Cat. No. IRI 019
C HR |
With capacity of 8 Viscometers |
Cat. No. IRI 019
E HR |
With capacity of 2 Viscometers
|
Accessory
19-031 |
Viscometer
holder, universal type |
Accessory
16-05 |
Pump-cum-stirrer,
output of 5-6 lpm at zero head (control accuracy ± 0.10C) |
Custom
Designs |
With
larger / smaller tanks, better accuracy, higher upper and temperature
…… |
Delivery
& Installation |
Personal
delivery strongly recommended. Refer Terms & Conditions
for details. |
Calibration
Certificate |
For
the digital display, at minimum 3 points, traceable to national
standards from a Govt. of India Lab |
6C
INSREF Digital Ultra Low
Temp Viscometer Bath, Cat. No. IRI 027 HR
…for
sub-zero temperatures, with non-CFC refrigeration & frost free
viewing window
Used for determination
of Kinematic Viscosity at temperatures at sub-zero temperatures.
Provided with built-in non-CFC refrigeration system, evacuated frost-free
windows for near-clear visibility even at sub-zero temperatures.
Can also be used for other low temperature tests such as Freezing
Point, Cloud Point, Pour Point etc.
Click
here for Specification Sheet.
Cat.
No. IRI 027 HR |
INSREF
Digital Ultra Low Temperature Viscometer Bath |
|
Generally
as per requirements under ASTM D 445 & equivalent
Digital Display with resolution of 0.010 C
Proportional temperature Control to within ± 0.030C
@ -200 C
Evacuated,
triple walled, toughened glass, frost free window
Long life, high safety zone, stainless steel immersion heaters
Drain to empty tank almost fully
Automatic high temperature & low water level safety cut-off
Tray to hold viscometers attached to viscometer holers1,
having 3- point alignment facility for each viscometer and port
for reference thermometer
With long life, low wattage, compact fluorescent lighting attachment
to enhance sample & viscometer visibility
|
Cat. No. IRI 027 A HR |
With capacity of 4 Viscometers
Operating temperature range of minus (-) 250C
to 00C
Operating temperature
range of minus (-) 750C to 00C
|
Cat. No. IRI 027 E HR |
With capacity of 2 Viscometers
Operating temperature range of minus (-) 250C
to 00C
Operating temperature
range of minus (-) 750C to 00C
|
Accessory
27-011 |
Viscometer
holder, universal type |
Accessory
27-02 |
Tray
with copper jackets, gasket, disk, test jars, corks for use
in Cloud & Pour Point determination (Two positions) |
Accessory
27-03 |
Tray
with provision for holding sample tubes, including sample tubes,
rubber corks, stirrer for Freezing Point determination Two positions) |
Custom
Designs |
With
larger / smaller tanks, better accuracy, higher upper and temperature
…… |
Delivery
& Installation |
Personal
delivery strongly recommended. Refer Terms & Conditions
for details. |
Calibration
Certificate |
For
the digital display, at minimum 3 points, traceable to national
standards from a Govt. of India Lab |
Thermometers
for use with above Viscosity Baths
Specification
No. |
Temperature
Range (0C) X Resolution / Name
|
IP
1 C / ASTM 5 C |
-38
to 50 X 1.0 / Cloud & Pour
|
IP
2 C / ASTM 6 C |
-80
to 20 X 1.0 / Low Cloud & Pour
|
IP
14 C / ASTM 114 C |
-80
to 20 X 0.5 / Aviation Tubine Fuel Freezing
|
IP
29 C / ASTM 44 C |
18.6
to 21.4 X 0.05 / Kinematic Viscosity, 200C
|
IP
30 C / ASTM 45 C |
23.6
to 26.4 X 0.05 / Kinematic Viscosity, 250C
|
IP
31 C / ASTM 28 C |
36.6
to 39.4 X 0.05 / Kinematic Viscosity, 37.80C
|
IP
32 C / --- |
98.6
to 101.4 X 0.05 / Kinematic Viscosity, 98.90C (1000C)
|
IP
33 C / ASTM 128 C |
-2
to 2 X 0.05 / Kinematic Viscosity, 00C
|
IP
34 C / ASTM 29 C |
52.5
to 56.5 X 0.05 / Kinematic Viscosity, 54.40C
|
IP
35 C / ASTM 47 C |
58
to 62 X 0.05 / Kinematic Viscosity, 600C
|
IP
36 C / ASTM 129 C |
91
to 95 X 0.05 / Kinematic Viscosity, 93.30C
|
IP
66 C / ASTM 46 C |
-51.6
to –34 X 0.1 / Kinematic Viscosity Low
|
IP
67 C / ASTM 72 C |
-48.6
to –51.4 X 0.05 / Kinematic Viscosity Low, -500C
|
IP
65 C / ASTM 43 C |
-19.2
to –16.4 X 0.05 / Kinematic Viscosity Low, -17.80C
|
IP
68 C / ASTM 73 C |
-41.4
to –38.6 X 0.05 / Kinematic Viscosity Low, -400C
|
IP
69 C / ASTM 74 C |
-55.3
to –52.5 X 0.05 / Kinematic Viscosity Low, -53.90C
|
IP
71 C / ASTM 126 C |
-27.5
to –24.7 X 0.05 / Kinematic Viscosity Low, -21.60C
|
IP
90 C / ASTM 48 C |
80.8
to 83.6 X 0.05 / Kinematic Viscosity, 82.20C
|
IP
92 C / --- |
38.6
to 41.4 X 0.05 / Kinematic Viscosity, 400C
|
IP
93 C / ASTM 110 C |
133.6
to 141.4 X 0.05 / Kinematic Viscosity, 1350C
|
IP
99 C / ASTM 127 C |
-21.4
to –18.6 X 0.05 / Kinematic Viscosity, -200C
|
IP
100 C / --- |
78.6
to 81.4 X 0.05 / Kinematic Viscosity, -800C
|
---
/ ASTM 116 C |
18.9
to 25.1 X 0.01 / For Kinematic / Intrinsic Viscosity at 200C
|
---
/ ASTM 117 C |
23.9
to 30.1 X 0.01 / For Kinematic / Intrinsic Viscosity at 250C
|
OPTIONAL |
Thermometer
Manufacturer’s Calibration Certificate for resolution of 0.050C,
traceable to National Standards (for any of the above)
|
OPTIONAL |
Thermometer
Manufacturer’s Calibration Certificate for resolution of 0.010C,
traceable to National Standards (for any of the above)
|
OPTIONAL |
Thermometer
Manufacturer’s Calibration Certificate for resolution of 0.10C,
traceable to National Standards (for any of the above)
|
OPTIONAL |
Calibration
Certificate from Govt. of Indian lab, for resolution of 0.10C,
traceable to National Standards (for any of the above)
|
OPTIONAL |
Calibration
Certificate from DGCA recognized private lab, for resolution
upto 0.010C,
traceable to National Standards (for any of the above)
|
Viscometers
for use with above Viscosity Baths
Made
of annealed, low expansion borosilicate glass, with size, number
& serial number permanently etched
Cannon-Fenske
(Routine), Zeitfuchs, Cannon Manning Semi Micro, Suspended level
Miniature Suspended Level, Suspended Level (Shortened Form) – any
size
Ubbelhode, Cannon Fenske (Opaque) – any size
Calibration
Certificate for above viscometers from manufacturer.
|