NON
CFC LAB Freezers
Specification Sheet no. 034 / 1299
INSREF Ultra Low temperature Research Cabinet. Cat. No IRI 034
Polished Stainless Steel
Chamber with foamed - in - place Poly Urethane foam (PUF)
insulation
Powder coated, compact, double colour exterior with
pipe framework & sheet covers, with powder coated aluminum top
Large, PUF insulated outer door, with lining of acrylic / hylam /
polystyrene for maximum insulation and minimum frosting
Upright
(Vertical) Format
Sealing gasket: Magnetic for -20o C model
& double silicone for others
Meshed Stainless stell trays
Inner doors made of acrylic / hylam
Latch cum lock & heavy duty stainless stell hinges for
outer door
Wheels for easy mobility
Model |
Lowest
Temp. |
Cooling
@
-20oC |
Chamber
Volume |
Chamber
Size
(WxHxD) |
Approx
Outer Size
(WxHxD) |
V206 |
-20oC |
800
BTU |
6
Cu. Ft
(170 ltrs) |
20"x36"x15"
with 3 Inner
doors |
28"x63"x24" |
V406 |
-40oC |
1300
BTU |
V806 |
-80oC |
2000
BTU |
V2010 |
-20oC |
1300
BTU |
10
Cu. Ft
(270 ltrs)
|
24"x36"x20"
with 3 Inner
doors
|
32"x63"x30"
|
V4010 |
-40oC |
2200
BTU |
V8010 |
-80oC |
3300
BTU |
V2015 |
-20oC |
2200
BTU |
14
Cu. Ft
(370 ltrs)
|
24"x48"x21"
with 4 Inner
doors |
32"x78"x30"
|
V4015 |
-40oC |
3600
BTU |
V8015 |
-80oC |
5500
BTU |
|
Digital
Temperature display
with resolution of 0.1o C & control accuracy of +2 o
C and audio-visual alarm for temperature deviation Cooling is by air
cooled, fully balanced, long life mechanical systems, with single or
double stages (as required) uisng high-power fully sealed
compressors and environment frindly, no- CFC gases Built-in
Voltage Stabiliser with high voltage cut-offs Available in two
formats Chest (Horizontal) and Upright (Vertical)
OPTIONS
AVAILABLE
Smaller / larger chamber sizes
Higher Cooling Capacities
Calibration Certificates
Chart recorders, with battery back-up
Vacuum Ports
Protected electrical supply / output points inside chamber
up based, programmable controllers with computer interface
Battery back-up for controller with power fail alarm
Chest
(Horizontal) Format
Sealing gasket : Magnetic for -20o model &
double silicone for others
Low depth of chamber for easy access
Latch cum lock & heavy duty stainless stell hings for
doors
Model |
Lowest
Temp. |
Chamber
Volume |
Cooling
@
-20oC |
Chamber
Size
(WxHxD) |
Approx
Outer Size
(WxHxD) |
H207 |
-20oC |
7
Cu. Ft
(190 ltrs) |
800
BTU |
15"x48"x17" |
24"x66"x24" |
H407 |
-40oC |
1300
BTU |
H807 |
-80oC |
2000
BTU |
H2012 |
-20oC |
12
Cu. Ft
(325 ltrs) |
1300
BTU |
18"x48"x24"
|
27"x69"x24"
|
H4012 |
-40oC |
2200
BTU |
H8012 |
-80oC |
3300
BTU |
H2015 |
-20oC |
16
Cu. Ft
(430 ltrs) |
2200
BTU |
24"x48"x24" |
33"x72"x24"
|
H4015 |
-40oC |
3600
BTU |
H8015 |
-80oC |
5500
BTU |
|
west temperatures
typically reach within 90 to 120 minutes, at an ambient of 27o C
to 30 o C, at no load. The lowest reachable temperature
varies upto ±5% with ambient temperature, and level of equipment
maintenance. An air-conditioned environment is most suited, though
not absolutely necessary. while calculating space requirements based
on the above data, please take into account free air
circulation space of at least 12" on all sides of the
equipment. Dimensions are correct to ± 1".
The Digital Temperature Display is calibrated at our factory against
thermometers which have calibration certificates traceable to
national standards. Calibration Certificates from a Government of
India lab, traceable to national standards for individual
equipment can be given, at extra cost.
All equipment operate on 230V, 50 Hz Single Phase AC power and come
with a 6 feet power chord, without plug.
Specifications and descriptions as above are subject to change
without notice.
|